At Fire Safe International, we test and calibrate portable and fixed gas detectors used for oxygen, flammable-gas and toxic-gas monitoring.
A bump test exposes the detector to test gas to confirm that the sensor responds at the expected trigger point and that its audible, visual and vibrating alarms operate.
Calibration goes further by applying a certified gas concentration, checking the displayed reading against that reference and adjusting the instrument where necessary.
During the service, our technicians identify the detector, fitted sensors, measurement ranges and alarm settings before inspecting the inlets, filters, pump, tubing, battery, display and warning devices. The instrument is then zeroed, exposed to the correct test gas at the specified flow rate and tested again after any adjustment to verify the final reading and alarm response.
Testing the detector in the configuration you depend on
We always use the test gas, regulator and tubing specified for the detector and the gas it is intended to measure. This is especially important for reactive gases such as ammonia or chlorine, which can be absorbed by unsuitable sampling equipment, and for flammable vapours that require a manufacturer-approved correction factor.
For pumped portable detectors, we can also check the probe, pump and sample tubing for leakage, blockage and delayed response. For fixed systems, the agreed test can extend beyond the sensor head to the controller, beacons, sounders, relays and shutdown outputs.
Each instrument is returned to you with a clear record of the gas applied, readings obtained, adjustments made, alarm operation and return-to-service decision.
Who we help
Our gas detection calibration service is primarily designed for people responsible for managing gas detection equipment and testing programmes. Our customers use the service for a variety of portable, pumps, and fixed instruments used in confined-space entry work, process work, shutdowns, hot work, and emergency response applications.
Why work with Fire Safe International?
Our team bring a wide range of confined-space, emergency-response and respiratory-protection experience to the calibration conversation. That means you can discuss a detector in the context of the entry, process or alarm duty it serves, without first teaching a general calibration provider how the instrument is used. We also work with portable, fixed, single-gas and multi-gas equipment from many manufacturers, making us a practical choice of service provider for mixed fleets. When an instrument repeatedly causes concern, you’ll have access to experienced engineers who can ask the right questions and help you decide whether recalibration, repair or replacement deserves attention.
Is bump testing enough?
Can calibration be carried out on-site?
What happens if a detector fails?
Why is calibration important?